Yamaha YZF-R6T Supplementary Service Manual page 245

Hide thumbs Also See for YZF-R6T:
Table of Contents

Advertisement

Manuals by Motomatrix / www.motomatrix.co.uk / The Solution For Lost Motorcycle Coded Keys
Charging method using a variable-current (voltage) charger
Adjust the voltage so that the
current is at the standard
charging level.
Set the time according to the
charging time suitable for the
open-circuit voltage.
Refer to "Battery condition
checking steps".
If charging requires more than 5 hours, it is advisable to check the
charging current after a lapse of 5 hours. If there is any change in the
amperage, readjust the voltage to obtain the standard charging
current.
Measure the battery open-circuit voltage after leaving the battery
unused for more than 30 minutes.
12.8 V or more --- Charging is complete.
12.7 V or less --- Recharging is required.
Under 12.0 V --- Replace the battery.
email: info@motomatrix.co.uk
CHECKING AND CHARGING THE BATTERY
Measure the open-circuit
voltage prior to charging.
Connect a charged and
AMP meter to the battery
and start charging.
Make sure that the current
YES
is higher than the standard
charging current written on
the battery.
By turning the charging
voltage adjust dial, set the
charging voltage at 20 X 24 V.
Monitor the amperage for
YES
3 X 5 minutes to check if the
standard charging current is
reached.
If the current does not
exceed the standard
charging current after 5
minutes, replace the battery.
3-62
CHK
ADJ
NOTE:
Voltage should be measured 30
minutes after the machine is stopped.
NOTE:
Set the charging voltage at 16 X 17 V.
(If the setting is lower, charging will be
insufficient. If too high, the battery will
be over-charged.)
NO
NO

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yzf-r6tcYzf-r6rYzf-r6srYzf-r6rcYzf-r6src

Table of Contents