KVH Industries LTD9116MKIT User Manual page 236

Maritime broadband systems
Table of Contents

Advertisement

Chapter 5: Troubleshooting
ID
08046
Timeout of
startup
sequence - No
antenna or
antenna
temperature too
low
08048
All PoE ports
except port 1
are shut down
due to high
temperature
08049
Data rate
reduction due
to high
temperature
0804B
Illegal
combination of
antenna and
terminal
224
Event Text
Status signalling
Explanation
The start-up
sequence of the
terminal has timed
out because:
the antenna is
not properly
connected, or
the antenna
temperature is
too low to start
up.
The temperature in
the terminal is too
high. All PoE ports
except port 1 are shut
down to reduce the
temperature.
The bit rate of the
data channel is
reduced because the
temperature is too
high.
You are not using the
right combination of
antenna and
terminal.
Remedy
Check that the
antenna cable is
properly connected
at both ends.
Move the terminal to
a cooler location, or
avoid using PoE on
port 2-4.
Move the terminal to
a cooler location
Only use the
antenna(s) intended
for use with your
terminal.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tracphone fb250Tracphone fb500

Table of Contents