KVH Industries LTD9116MKIT User Manual page 233

Maritime broadband systems
Table of Contents

Advertisement

ID
Event Text
0800D
Antenna
Overvoltage
protection is
activated
08010
Undervoltage
has been
detected
0801B
Lost connection
to the GPS
receiver
0801D
Uploading
firmware to
antenna
0802C
Firmware update
still fails
after several
retries
0802D
Firmware update
failed
Explanation
Overvoltage is
detected in the
antenna. The
terminal will be shut
down in 10 minutes.
The input voltage has
dropped below an
acceptable level. The
terminal will be shut
down in 10 seconds if
the situation persists.
Communication with
the GPS receiver in
the antenna is lost.
New firmware is
being uploaded to
the antenna.
The Event will be
cleared when upload
has finished.
The terminal was
unable to upload
new firmware to the
antenna.
The terminal was
unable to upload
new firmware to the
antenna.
Status signalling
Chapter 5: Troubleshooting
Remedy
Do not use the
terminal.
Contact your
distributor.
Ensure a stable
power supply to the
terminal.
Contact your
distributor if the
warning persists.
Contact your
distributor if the
Event is not cleared
within 5 minutes.
Contact your
distributor.
Reboot the terminal.
Contact your
distributor if the
problem persists.