Problem
A LAN
The cable is not
connection
properly connected.
cannot be
The cable type or
established.
connector type is not
correct.
The connected
equipment is set up to
use a static IP address
and
1. the IP address is
2. the terminal is set
Possible Cause
reserved for
internal use in the
terminal, or
up to assign a
dynamic IP
address to the
equipment.
Troubleshooting guide
Chapter 5: Troubleshooting
Remedy
Connect the cable.
For information on the correct type of
connector and cable, refer to the
installation manual.
Do one of the following:
1. Change the IP address of the
connected equipment to an IP
address that is not reserved. See
List of reserved IP subnets on
page 231.
2. Set up the equipment to use a
dynamic IP address, or disable
DHCP in the terminal. See step 2 in
the section Setting up the local LAN
IP addresses on page 105.