KVH Industries LTD9116MKIT User Manual page 228

Maritime broadband systems
Table of Contents

Advertisement

Chapter 5: Troubleshooting
ID
01110 to
Temperature too
01119
high (critical)
01120 to
Too high
01129
temperature
warning
01300 to
No GPS fix
01309
216
Event Text
Status signalling
Explanation
Terminal: Critically
high temperature is
causing the terminal
to shut down.
Antenna: Critically
high temperature is
causing the antenna
to stop transmission.
High ambient
temperature is
causing the
performance of the
system to be
degraded or halted.
If the problem is in
the terminal: All PoE
ports are shut down,
except port 1 and the
bit rate for Standard
data is reduced.
If the problem is in
the antenna: The bit
rate is reduced.
The GPS receiver has
not yet achieved
position fix.
Remedy
If possible, move the
failing unit to a
cooler location.
For information on
ambient temperature
limits, see the
installation manual.
Contact your
distributor if the
problem persists.
Move the terminal to
a cooler location.
For information on
ambient temperature
limits, see the
installation manual.
Make sure the view
to the GPS satellites
is not blocked.
Note that in some
cases it may take up
to 10 minutes to
obtain GPS fix.

Advertisement