KVH Industries LTD9116MKIT User Manual page 235

Maritime broadband systems
Table of Contents

Advertisement

ID
Event Text
08035
Unable to open
port for HPA
burst
monitoring
08036
Radio silence
is activated
08040
Excessive
writes to the
flash memory
08045
Antenna -
Startup
temperature too
low
Explanation
There was an error
communicating with
the antenna.
The Radio silence
function is activated.
No transmission is
allowed.
Wrong APN name or
username/
password for a
profile which is set to
auto-activate.
The temperature in
the antenna is too
low for the system to
start up
Status signalling
Chapter 5: Troubleshooting
Remedy
Reboot the terminal.
Contact your
distributor if the
problem persists.
If the Radio silence
function should not
be active, enter the
web interface and
select SETTINGS >
Discrete I/O. Then
uncheck the Enabled
box for Radio silence.
Check that the APN
name, username and
password are set up
correctly for your
profiles.
None. If the ambient
temperature is
outside the specified
limits, the antenna
may not be able to
start up properly.
Refer to the
installation manual
for temperature
specifications.
223

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tracphone fb250Tracphone fb500

Table of Contents