ID
Event Text
03500 to
2-wire
03509
calibration
failure
03600 to
2-wire
03609
operational
failure
Explanation
2-wire calibration
failed on the
Phone/Fax interface,
because of:
1. Common mode
balance error.
2. The phone is off
hook.
3. Wires are shorted
to each other or
shorted to
ground.
The Phone/Fax
interface fails to
operate, for one of
the following
reasons:
1. Ground shorted.
2. Power overload.
3. Temperature
overload.
Status signalling
Chapter 5: Troubleshooting
Remedy
1. Check the wires
to your phone or
fax.
2. Put the phone on
hook.
3. Check the wires.
1. Check the wires.
2. Wait until the
event is cleared;
then try again.
3. Wait until the
event is cleared;
then try again.
219