2. Type in the Server IP address, Server port, Client port and Encryption key
for your server connection.
IP address. The IP address of the server that the TracPhone terminal
will report to.
Server port. Port number on the server. Default number is 7474.
Client port. Port number on the TracPhone terminal. Default number is
7475.
Encryption key. A pre-shared 128 bit key which must match on both the
client and server side.
3. To allow remote control of the tracking settings from the tracking server,
select Yes at Allow remote control.
This means the TracPhone terminal will accept commands from the
specified tracking server, for example to change reporting intervals or
start/stop reporting.
4. Select the APN to use for Tracking. You have the following options:
Common. The APN is taken from the Common APN defined under
SETTINGS > Common. Refer to Setting the common interface settings on
page 117.
SIM default. The APN is taken from the SIM card. This is the
recommended option, unless you have special requirements.
Network assigned. The APN is assigned from the network.
User defined. Type in the APN. APNs are provided from the Airtime
Provider.
5. Under Position reports, select the report type you want to use.
Compressed. Only latitude and longitude are reported.
Extended. Apart from latitude and longitude, heading and altitude are
also included.
ECEF. The same information as Extended, but position and speed data
are 3D (ECEF coordinates).
6. Under Interval report, select Enabled or Disabled and type in the interval
between the reports.
Chapter 4: Using the web interface