EPSON Stylus Pro 7400/7800/9400/9800
5.2.7 PF Encoder Sensor Adjustment
This adjustment is intended to maintain a proper gap between the PF Encoder Sensor
and the PF Loop Scale.
No tool is required
Procedure
1.
Loosen the two screws that secure the PF Encoder Mounting Plate. Adjust the
plate position visually so that the PF Loop Scale runs through the center of the
slit of the PF Encoder Sensor.
Adjustment
PF Encoder Mounting Plate
Figure 5-18. PF Encoder Sensor Adjustment
Mechanical Adjustment
PF Loop Scale
Securing Screws
Revision B
PF Encoder
Sensor
PF Loop Scale
PF Encoder
Sensor
309