Release K.13.45 - HP ProCurve 3500yl Release Notes

Software version k.13.49
Hide thumbs Also See for ProCurve 3500yl:
Table of Contents

Advertisement

Software Fixes in Release K.11.12 - K.13.49

Release K.13.45

CLI (PR_1000803731) — If the "|" character exists in the banner text of a configuration
file downloaded via TFTP transfer, the banner text may become corrupted, or the TFTP
transfer may fail with a corrupted download file error message.
Hang (PR_0000007806) — Using the CLI command no arp on ARP entries that do not exist
may cause the switch to hang.
CLI (PR_0000008617) — The copy command for USB options has incorrect optional
parameters for plain text files.
RADIUS Accounting (PR_0000004139) — Procurve switches do not send the
accounting-request to a RADIUS server upon execution of the reload CLI command.
RADIUS Accounting (PR_0000004145) — An incomplete "Calling-Station-ID" field is
sent in the accounting-request to the RADIUS server upon execution of the boot system CLI
command.
RADIUS Accounting (PR_0000004141) — The "Acct-Status-Type" attribute is missing in
the accounting-request to RADIUS server upon execution of the boot system CLI command.
Terminal Display (PR_0000008238) — The default boot message is displayed with the
wrong formatting if the terminal width is changed.
CLI (PR_0000008236) — The enable CLI command is listed in enable-mode help.
UDLD (PR_0000009505) — UDLD misconfiguration (where UDLD is enabled on one side
and disabled on the other) could lead to a unicast packet storm which results in MSTP is
running with multiple roots.
CLI (PR_0000008217) — The copy flash CLI command does not allow the user to specify
a source OS location (primary/secondary).
Release K.13.45
The following problems were resolved in release K.13.45.
STP (PR_0000010815) — When a switch configured with BPDU protection is added to a
network, if the MSTP configuration of the uplink port is changed from auto-edge to no
auto-edge there is a topology change event that takes place as the switch asserts itself as a
new root.
Enhancement (PR_0000010783) — Support was added for the following products.
J9099B - ProCurve 100-BX-D SFP-LC Transceiver
J9100B - ProCurve 100-BX-U SFP-LC Transceiver
J9142B - ProCurve 1000-BX-D SFP-LC Mini-GBIC