Software Fixes In Release K.11.12 - K.13.49; Release K.11.12 - HP ProCurve 3500yl Release Notes

Software version k.13.49
Hide thumbs Also See for ProCurve 3500yl:
Table of Contents

Advertisement

Software Fixes in Release K.11.12 - K.13.49

Release K.11.12

Software Fixes in Release K.11.12 - K.13.49
Software fixes are listed in chronological order, oldest to newest.
Unless otherwise noted, each new release includes the software fixes added in all previous releases.
Release K.11.11 was the first production software release for the ProCurve 3500yl, 6200yl, and 5400zl
Series switches. Release K.11.69 is the last release of the K.11.xx software. The 3500yl, 6200yl, and
5400zl switch series software code was rolled to the K.12.00 code branch with no intervening releases.
The first production software release for the 8212zl switch is K.12.31. Release K.12.57 is the last public
release of the K.12.xx software. The 3500yl, 6200yl, 5400zl, and 8212zl software code was rolled to
the K.13.0x code branch with no intervening releases.
Release K.11.12
The following problems were resolved in release K.11.12 (never released)
ACL/QoS (PR_1000317233) — Under some circumstances, the Switch may apply an ACL
or QoS configuration setting incorrectly.
Configuration/Security (PR_1000316441) — Operator level can save Manager privilege
level changes to the configuration.
Crash Log (PR_1000309533) — Incorrect crash message displayed in the log, "Too many
HSL interrupts".
Crash (PR_1000317489) — Changing the QoS/ACL portion of the running configuration
may cause a switch module to crash with a message similar to:
CL Int status=0x10000000
Gig-T SFP Modules (PR_1000316433) — The switch accepts a Gig-T SFP dual personality
module when it should not accept these modules.w
Help file enhancement (PR_1000300491) — Added support for Help files. Switch can
provide a navigation pane on the left side of the screen containing 'Contents' and 'Search'
capability.
10 Gig Transceiver (PR_1000317965) — Switch reports incorrect Link status when a
defective fiber cable is connected to the Switch.
LED (PR_1000316434) — If a mini-GBIC is installed during switch bootup, that port's link
LED will not turn on.