sFlow (PR_1000361604) — Changed the maximum sFlow skipcount to 24 bits.
■
Release K.11.61
Versions K.11.50 through K.11.59 were never built.
Version K.11.60 was never released.
The following problems were resolved in release K.11.61 (not a general release)
■
802.1X (PR_1000367404) — Increased the maximum number of 802.1X users per port to
32.
Crash (PR_1000366583) — When a large config is saved using the "write memory" CLI
■
command, the switch may crash with a message similar to:
NMI event SW:IP=0x00897870 MSR:0x00029210 LR:0x00100c80 Task='mSess1'
Task ID=0x8d13fe0.
Release K.11.62
The following problems were resolved in release K.11.62 (not a general release)
ACL (PR_1000368901) — Outbound access control lists (ACLs) do not function after a
■
reboot.
■
Authorization (PR_1000365285) — IP Authorized Managers feature behaves incorrectly
with regard to Telnet access.
CLI (PR_1000313916) — The CLI output for the "show ip" command is misaligned; the
■
proxy-arp column is shifted over to the left by one.
■
Crash (PR_1000356446) — When traffic monitoring is in use, the switch may crash with
a message similar to this.
Data Bus Error: Addr=0x704a6114 Data=0x00000011 flags=0x10000751,
IP=0x4012eaac Task='mEaseUpdt' TaskID=0x42fef338
■
Routing (PR_1000350144) — Adding a VLAN and assigning an IP address to that VLAN
through the menu interface takes routing information protocol (RIP) offline in all VLANs.
■
sFlow (PR_1000361604) — Changed the maximum sFlow skipcount to 24 bits.
VLAN (PR_1000356062) — When configuring from the menu interface, the 3500yl series
■
switches will not allow the following name format for a new VLAN:
"VLANx" (where "x" is a VLAN number).
Software Fixes in Release K.11.12 - K.13.49
Release K.11.61
156
Need help?
Do you have a question about the ProCurve 3500yl and is the answer not in the manual?