Release K.11.63; Release K.11.64 - HP ProCurve 3500yl Release Notes

Software version k.13.49
Hide thumbs Also See for ProCurve 3500yl:
Table of Contents

Advertisement

Software Fixes in Release K.11.12 - K.13.49

Release K.11.63

Release K.11.63
The following problems were resolved in release K.11.63
802.1p QoS (PR_1000368188) — 802.1p prioritization may not work once a trunk is
enabled on a module, unless the user issues the commands "qos type-of service
ip-precedence" or "qos type-of service diff-services".
Crash (PR_1000368540) — The switch may crash with a message similar to:
Software exception at parser.c:8012 -- in 'mSess2',
task ID = 0x90e10e0 -> ASSERT: failed.
Menu/Event Log (PR_1000319407) — Disabling of event log numbers, via the "no
log-numbers" CLI command, doesn't work properly when viewing the event log via the Menu.
Using the 'next' and 'prev' buttons causes the log numbers to reappear.
PCM Traffic Monitoring/Performance Degradation (PR_1000370061) — The switch
is affected by PCM traffic monitoring, causing throughput degradation.
RADIUS (PR_1000358525) — Attributes that were overridden by RADIUS (CoS, Rate, and
ACL) remain active if an authenticated user fails to send EAP-LOGOFF.

Release K.11.64

The following problems were resolved in release K.11.64 (not a general release)
Crash (PR_1000372604) — When multiple of instances of sFlow have been configured via
the CLI, the switch may crash with an error similar to:
Software exception at sflow.c:1170 -- in 'mEaseCtrl',
task ID = 0x80e5fe0-> ASSERT:
Enhancement (PR_1000376406) — Loop Protection feature additions, including packet
authentication, loop detected trap, and receiver port configuration.
Event Log (PR_1000373796) — Selecting "Save", within the IP Configuration screen of
the Menu causes unnecessary Event Log messages.
sFlow/Flow-Control (PR_1000375851) — To protect performance if Flow-Control is
enabled on any one or more ports , egress sFlow sampling will be disabled on all ports and
a CLI/Event Log message will be generated.
VLAN/CLI (PR_1000368900) — VLAN names over 12 characters in length cause the output
from the command "show ip route" to be displayed incorrectly.