Config (PR_1000781031) — When the valid port setting 'auto-1000' is configured for any
■
10/100/1000 interface in an external configuration file and the configuration file is copied to
the switch, the system returns the port setting to the default value, changing 'auto-1000' to
'auto.'
CLI (PR_0000004687) — The CLI command ip access-list resequence <name-str> does
■
not accept a number for the ACL title as it should.
■
PIM-SM (PR_0000006180) — PIM Sparse Mode may choose an incorrect rendezvous point
(RP), causing interoperability problems. This fix changes the way a RP is chosen such that
ALL the devices running "K" versions of software must be on either pre- or post-fix software
version in order to use the same criteria to choose the PIM RP.
■
Event Log (PR_1000755803) — ProCurve Manager is unable to display a link to the switch
Web Interface in events generated by Fault Finder.
Release K.13.22
The following problems were resolved in release K.13.22 (not a public release).
■
CLI (PR_0000002856/1000769143) — The switch is unable to execute the CLI command
show tech while in QinQ svlan mode.
■
OSPF (PR_0000006183) — OSPF ECMP may drop up to 50% of the traffic destined for its
next hop.
Mini-GBIC (PR_0000006298) — Mini-GBICs in dual-personality ports fail self-test when
■
the switch is running K.13.20-K.13.21. Workaround: Configure fastboot.
Licensing (PR_0000006554) — An invalid hardware ID (required for Premium Licensing
■
in 3500yl and 5400zl switches) is created by switches running K.13.15 - K.13.21.
Release K.13.23
The following problems were resolved in release K.13.23.
Crash (PR_0000006624) — When using the Web Management Interface on software
■
version K.13.17 and higher, the switch may crash if the "Configuration" and then "IP
Configuration" tabs are clicked. There may be other triggers for this crash. The switch will
display a message similar to the following.
PPC Data Storage (Bus Error) exception vector 0x300: Stack
Frame=0x0815da48 HW Addr=0xa2d3e193 IP=0x00169178
Task='tHttpd' Task ID=0x fp: 0x00a650c4 sp:
Software Fixes in Release K.11.12 - K.13.49
Release K.13.22
198
Need help?
Do you have a question about the ProCurve 3500yl and is the answer not in the manual?
Questions and answers