Software Fixes in Release K.11.12 - K.13.49

Release K.12.22

Routing (PR_1000432449) — If the switch is configured with both port security and
routing, a physical port transition on the host may cause the switch to stop transmitting
routed traffic to that host. Clearing the ARP cache resolves this problem until another port
transition occurs.
RADIUS (PR_1000442879) — If RADIUS (or TACACS+) keys are configured, and then the
switch is updated to a software revision with the ability to save the security credentials in
the configuration file (K.12.06 or later), the RADIUS keys are no longer shown in output from
the "show run" or "show config" commands until the "include-credentials" command is
issued.
Release K.12.22
The following problems were resolved in release K.12.22.
Enhancement (PR_1000443026) — Support for the new revision "C" Mini-GBICs was
added to the CLI and the "show tech" command.
Enhancement (PR_1000444415) — OSPF Passive Interface support was added.
Crash (PR_1000442695) — Pasting a VRRP configuration into the running configuration
via a Telnet session may cause the switch to crash with a message similar to:
Software exception at vrrp_statemach.c:205 -- in 'mVrrpCtrl', task
ID = 0x8b154a0-> internal error

Release K.12.23

The following problems were resolved in release K.12.23.
Crash (PR_1000415534) — Execution of the "lockout-mac" CLI command, may cause the
switch to crash with a message similar to:
PPC Data Storage (Bus Error) exception vector 0x300: Stack
Frame=0x0ab9a738 HW Addr=0x00b3f104 IP=0x00801d2c Task='eDrvPoll'
Task ID=0xab9ad20 fp: 0x0f3808c0 sp
AAA/CLI (PR_1000445886) — This changes the syntax of 'aaa authentication
<port-access | mac-based | web-based>' commands which were previously added in
PR_1000438486.
CLI (PR_1000403478) — Power over Ethernet (802.3af) CLI commands were removed
from platforms that do not support PoE (such as the ProCurve 6200yl switch).
Broadcast-limit (PR_1000429594) — The broadcast limit feature affects multicast traffic.
This fix modifies the feature so that it only affects broadcast traffic.