By Type
To view the log information of a particular type: (Major and Minor)
Major types include: Operation, Alarm, Exception and All.
For each major type there are associated minor types including: Power On, Shut Down,
Abnormal Shut, Panel Login, Panel Logout, Panel Config., Panel File Play, Panel Time
Play, Local Start Record, Local Stop Record, Panel PTZ, Panel Preview, Panel Set Time,
Local Upgrade, Net Login, Net Logout, Net Start Record, Net Stop Record, Net Start
Transparent Channel, Net Stop Transparent Channel, Net Get Parameter, Net Config, Net
get Status, Net Alert On, Net Alert Off, Net Reboot, BiComStart (start audio), BiComStop
(Stop audio), Net Upgrade, Net File Play, Net Time Play, Net PTZ.
Alarm Types: Alarm major type, the minor type includes: External Alarm In, External
Alarm Out, Motion Detect Start, Motion Detect Stop, View Tamper Start, and View
Tamper Stop.
For exception major type, the minor type includes: Video Signal Loss, Illegal Access,
Hard Disk Error, Hard Disk Full, IP Conflict, and DCD Lost.
Viewing the Alarm Log:
1. Select a Query type, a Major For "Query" item, select "By Type" to active "Major Type"
and "Minor Type" items.
2. For "Major Type" option, select "Alarm" option. For "Minor Type" option, select one of
127