Username, password and Verify password: Only used in "PPP" mode. Used for login
when a remote PC dialup connection is made through PSTN.
Phone: Only used in "PPP" mode. This is the phone number of the remote PC.
Callback and Data Encryption: Only used in "PPP" mode. They are not currently
available.
Confirm: Save parameters and return main menu.
Cancel: Abort modification and return main menu.
Example: PPP (Modem) passive dialup through PSTN
There are two Modems. One is connected DVR RS-232 port with DCE cable. The other is
connected with PC COM port.
Setup at DVR end:
RS232 setup: Setup baud rate, data bit, stop bit, parity and flow control. Settings must be the
same as those of the modem connected to the PC.
Video setup In "Recording" menu, select the camera you want to transfer through PSTN.
If you set CIF resolution, we suggest you set frame rate as 1 FPS. If you set QCIF
resolution, the frame rate can be selected at 4FPS. You can adjust the bit rate, resolution
and frame rate, according to real conditions, in DVR "Recording" menu.
Save setup In "Recording" menu, press "Confirm" button to save parameters.
Setup Modem used on DVR side Use DCE cable to connect the Modem to the PC serial
port. You can use HyperTerminal or NetTerm to setup the modem:
AT&F ---- Restore default parameters (Generally, Modem is hard flow control)
AT&S0=1---- Set Modem as answer
ATE0 ---- Not display the input characters
ATQ1 ---- Commit instruction and not display
AT&W&W1 ---- Save parameters