DMI Event Log Messages
Log info
Log info2
Error
Memory
0100
Correctable
Error
0200
Error
0300
Error
0400
Error
Memory
0100
Uncorrecta
ble
Error
0200
Error
0300
Error
0400
Error
PCI PERR
XXXX
Error
PCI SERR
XXXX
Error
PCIe
80XX
UncErr
Error
90XX
Error
A0XX
Error
B0XX
POST
POST Error
Error
Code:
XXXX
WDT
WDT
00XX
timeout
WDT
00C0
WDT
01C0
Log
Area
(None)
Cleared
System
(None)
Boot
Description
Info:
A correctable error
occurred for DIMM #1.
Info:
A correctable error
occurred for DIMM #2.
Info:
A correctable error
occurred for DIMM #3.
Info:
A correctable error
occurred for DIMM #4.
Info:
An uncorrectable error
occurred for DIMM #1.
Info:
An uncorrectable error
occurred for DIMM #2.
Info:
An uncorrectable error
occurred for DIMM #3.
Info:
An uncorrectable error
occurred for DIMM #4.
Info:
A parity error occurred
for PCI #4.
Info:
A
system
occurred for PCI #4.
Info:
An uncorrectable error
occurred
for
on-board LAN.
Info:
An uncorrectable error
occurred for PCI #1.
Info:
An uncorrectable error
occurred for PCI #2.
Info:
An uncorrectable error
occurred for PCI #3.
A
POST
occurred.
Info:
The watchdog timer
timed out last time the
POST was started.
Info:
The watchdog timer
timed out last time the
OS was started.
Info:
The watchdog timer
timed out last time the
OS was running.
The DMI log area was
initialized and the log
was deleted.
The POST finished.
Recommended action
Restart the equipment, and then run the
BIOS SETUP utility. Check the DIMM status
(DIMM Group #1 to #4 Status) displayed in
"Memory Configuration", which is on the
Advanced menu.
Check whether the DIMM for which the error
occurred is inserted correctly, and then
restart the equipment. If this does not
resolve the problem, contact your service
representative.
Restart the equipment, and then run the
BIOS SETUP utility. Check the DIMM status
(DIMM Group #1 to #4 Status) displayed in
"Memory Configuration", which is on the
Advanced menu.
Check whether the DIMM for which the error
occurred is inserted correctly, and then
restart the equipment. If this does not
resolve the problem, contact your service
representative.
Check whether the optional card in PCI slot
#4 is inserted correctly, and then restart the
error
equipment. If this does not resolve the
problem, contact your service
representative.
Restart the equipment. If this does not
the
resolve the problem, contact your service
representative.
Check whether the optional card in the PCI
slot for which the error occurred is inserted
correctly, and then restart the equipment. If
this does not resolve the problem, contact
your service representative.
error
For the recommended action, see "POST
Error Messages".
Restart the equipment. If this does not
resolve the problem, contact your service
representative.
Restart the equipment. If this does not
resolve the problem, contact your service
representative.
Restart the equipment. If this does not
resolve the problem, contact your service
representative.
This is not an error.
This is not an error.