Troubleshooting - NEC Express5800 User Manual

Hide thumbs Also See for Express5800:
Table of Contents

Advertisement

Error
Error message
code
0615
Com B configuration changed
0616
Com B config. error - device
disabled
0B00
WDT timeout occurred at previous
boot in POST.
0B01
WDT timeout occurred at previous
boot in OS boot.
0B02
WDT timeout occurred at previous
boot in OS running.
0B28
Unsupported CPU detect on CPU
Slot
0B60
DIMM group #1 has been disabled
0B61
DIMM group #2 has been disabled
0B62
DIMM group #3 has been disabled
0B63
DIMM group #4 has been disabled
0B6F
DIMM group with error is enabled
Mismatched FAN control Mode
0B7E
setting. Please set the FAN control
mode on BIOS SETUP.
0BB0
SMBIOS - SROM data read error.
0BB1
SMBIOS - data checksum bad.
8151
Password Cleared By Jumper
8800
PECI - Communication Error
9000
PCI Slot#1 PCIE Link Training
Error.
9001
PCI Slot#2 PCIE Link Training
Error.
9002
PCI Slot#3 PCIE Link Training
Error.
-
Expansion ROM not initialized - PCI
Mass Storage Controller in slot xx
Recommended Action
Check if COM B is properly configured.
Reboot (reset) the server. If the server starts
normally, confirm the DMI log.
Contact your service representative.
Contact your service representative.
Run BIOS SETUP and provide setting again.
Contact your service representative.
Power off the server, then change the password clear
jumper switch to its original position.
Contact your service representative.
Remove the PCI card from the slot that shows an
error, then install the PCI card again. If the same
error persists, contact your service representative.
If the hard disk drive connected to RAID Controller or
LAN board (for network boot) does not contain any
OS, disable Option ROM Scan for that PCI slot.

Troubleshooting 8-7