Fujitsu PRIMERGY BX920 S3 Upgrade And Maintenance Manual page 79

Server blade
Hide thumbs Also See for PRIMERGY BX920 S3:
Table of Contents

Advertisement

Ê Deactivate the BIOS Recovery Flash Bit Enabled option in the management
blade Boot Options menu.
Ê Switch on the server blade as described in section
blade" on page
Ê You can now put the server blade back into operation.
Second option: Recovering the server blade BIOS via DIP switch
Ê Remove the server blade from the system unit as described in section
"Removing a server blade" on page
Ê Open the server blade as described in section
on page
58.
Ê Enter BIOS recovery mode using switch 3 of the user DIP switch bank, see
section
"Onboard settings" on page
Ê Close the server blade as described in section
page
59.
Ê Reinstall and secure the server blade in the system unit as described in
section
"Installing the server blade in the system unit" on page
Ê Connect the monitor, keyboard, mouse and USB memory stick to the port on
the front of the server blade using the Y cable, see the Operating Manual.
Ê Switch on the server blade as described in section
blade" on page
After a short beep, the BIOS upload is executed. The status of the Flash
operation is displayed on screen. Once the Flash operation is complete,
information on how to proceed is displayed:
V
CAUTION!
Do not interrupt the BIOS recovery process after it has started. If the
process is interrupted, the BIOS may be permanently corrupted.
Ê Switch off the server blade as described in section
blade" on page
Ê Remove the Y-cable.
Ê Remove the server blade from the system unit as described in section
"Removing a server blade" on page
BX920 S3
63.
63.
55.
Upgrade and Maintenance Manual
Basic software procedures
"Switching on the server
56.
"Opening the server blade"
259.
"Closing the server blade" on
"Switching on the server
"Shutting down the server
56.
60.
79