Minimum Startup Configuration - Fujitsu PRIMERGY BX920 S3 Upgrade And Maintenance Manual

Server blade
Hide thumbs Also See for PRIMERGY BX920 S3:
Table of Contents

Advertisement

Appendix
12.4

Minimum startup configuration

Field Replaceable Units (FRU)
If the server blade does not start up or other problems occur, it may be
necessary to take the system down to its most basic configuration in order to
isolate the defective component.
The minimum startup configuration consists of the following components:
Component
BX920 S3 server blade
1 CPU with heat sink
1 memory module
Table 7: Minimum startup configuration - components
Ê Shut down the server blade as described in section
server blade" on page
Ê Remove the server blade from the system unit as described in section
"Removing a server blade" on page
Ê Take the server blade down to its minimum startup configuration.
Ê Reinstall the server blade in the system unit as described in section
"Installing the server blade in the system unit" on page
Ê Switch on the server blade as described in section
blade" on page
Ê Login to the management blade web interface, see section
management blade web interface" on page
266
Notes and reference
Installed in slot CPU 1, see section
information" on page
Installed in socket DIMM 1A, see section
"Basic information" on page 164
55.
63.
Upgrade and Maintenance Manual
184.
"Shutting down the
56.
"Switching on the server
45.
"Basic
60.
"Accessing the