GE Multinet 4 Instruction Manual page 60

Multi-port serial server & managed switch
Table of Contents

Advertisement

ENERVISTA MULTINET4 SETUP SOFTWARE
3–4
7.
Select "Ethernet" from the Interface drop-down list. This will display a number
of interface parameters that must be entered for proper Ethernet
functionality.
8.
Enter the Multinet4 IP address in the "IP Address" field. If a new IP address is
desired at this point, the new IP address should be entered in the New IP
Address field in the Network Setting frame, and the current IP Address in the
IP Address field.
9.
New IP address information can be configured at this setup as well. Specify
the new IP address, Subnet mask and Gateway in the Network Setting frame
and then click Save.
10. Click the Read Order Code button to connect to the Multinet4 device and
upload the order code. If a communications error occurs, ensure that the IP
address correspond to the Multinet4 setting value.
11. EnerVista Multinet4 Setup software connects using the username "manager,"
and password "manage" by default, without a prompting Login dialog. If it
fails, the program prompts you to enter valid login credentials in order to
proceed further. If the authentication level is "Read-Write" or "Read Only" you
MULTINET4 MULTI-PORT SERIAL SERVER & MANAGED SWITCH – INSTRUCTION MANUAL