Standard Name
Power Transients (low repetition high
energy)
Transients I/O terminals
Surge Immunity
Non Destructive transient Immunity
Damped Oscillatory Burst
Damped Oscillatory
Voltage Dip / Voltage Interruption
Power Supply Ripple
RF Immunity 80-1000MHz
RF Immunity 80-1000MHz
Conducted RF Immunity 150Khz -80 MHz
Conducted RF Immunity 0-150Khz
Power Frequency Magnetic Field
Immunity
Damped Magnetic Immunity
Voltage Dips and Interrupts
Conducted & Radiated Emissions
Conducted & Radiated Emissions
Rated Input Power
AC voltage ranges
DC voltage ranges
ENVIRONMENTAL TESTS
Relative Humidity Cyclic
Cold Temperature
MULTINET4 MULTI-PORT SERIAL SERVER & MANAGED SWITCH – INSTRUCTION MANUAL
Standard Number:Date
code
NEMA TS2 :2003
NEMA TS2 2.1.7.1 :2003
IEC61000-4-5:2005
NEMA TS2:2003
EN/IEC61000-4-12 :2006
IEEE C37.90.1:2002
EN/IEC 61000-4-11 :2004
IEC 61000-4-17
EN/IEC 61000-4-3 :1998
IEEE C37.90.2:2004
IEC61000-4-6:1996
EN/IEC 61000-4-16:1998
EN/IEC 61000-4-8:1993,2001
IEC61000-4-10
IEC61000-4-29
CISPR22 / EN 55022
FCC Part 15 Subpart B
IEEE C37.90
IEC60870-2-1
IEC60870-2-1
EN/IEC 60068-2-30:2005
EN/IEC 60068-2-1: 1993/1990
OVERVIEW
Severity levels Tested
600V, 1 Ohm impedance
300V, 100 Ohms impedance
Serial: 4 kV on shield;
DC Power LO: 6kV L-E, 6kV L-L;
AC Power: 6kV L-E, 6kV L-L
1000V, 1 Ohm impedance
Level 2 - 1kV common / 1kV
differential
2.5 kV common mode / 1kV
differential mode @1MHz
0% 5000msec, 40% 120msec,
70% 10msec
Level 3 - 10% & 15% of Rated
Voltage
Level 3 - 10V/m
35V/m
Level 3 - 10Vrms
Level 3 - 15Hz-150Khz 1-10V
Level 4 - 15Hz-150KHz 1-30V
Level 5 - 100/200 A/m -
continuous 1000 A/m for 1s
Level 3 - 10A/m
All test levels and durations -
Passes Criteria B
Class A
Class A
85% to110% of rated
+ / - 10%
+ / - 15%
Variant 2 - 6 day @ 95%
-40 deg startup for 16 hours
1–5