Local Alarm Indication - Panasonic KX-TD500 User Manual

Digital super hybrid system
Hide thumbs Also See for KX-TD500:
Table of Contents

Advertisement

L
4.4

Local Alarm Indication

If a system error is detected during on-line communication mode, the system alerts the
Manager extension by turning on the Alarm button indicator on it. The Alarm button
lights in red. The Manager can confirm the error indication by pressing the red lit Alarm
button.
If a major error occurs, minor errors will be neglected and only the first major error
message will be displayed. The second error will be neglected, if the error priority is the
same as the first one. Please refer to "Section 7 Troubleshooting" in the Installation
Manual for further information on error messages.
Indications
ERR
ERR
B/S
FAN FLT!
E/S1 FAN FLT!
E/S2 FAN FLT!
B/S
OVER HEAT!
E/S1 OVER HEAT!
E/S2 OVER HEAT!
ERR
ERR
ERR
ERR xyy
ERR xyy
ERR xyy
ERR xyy
ERR xyy
ERR xyy
ERR xyy
ERR xyy
ERR xyye
ERR xyy
ERR xyy
ERR
4-210
Station Features and Operation
Operator / Manager Service Features
Error Indications List (Priority order)
Calendar IC failure
CLCK IC
DC power down
DC DOWN
Basic shelf fan alarm
Expansion shelf 1 fan alarm
Expansion shelf 2 fan alarm
Basic shelf heat alarm
Expansion shelf 1 heat alarm
Expansion shelf 2 heat alarm
TSW clock down
TSW DWN
BAT ALM
CPU RAM battery alarm
AC power down
AC DOWN
CRD ERR
Option Card failure
Card disconnect
DISCNCT
DTR AIS
Digital trunk AIS reception
Digital trunk frame failure
DTR FRM
Digital trunk RAI reception
DTR RAI
Digital trunk out of synchronization
DTR SYC
Option Card RAM failure
LPR RAM
Option Card ROM failure
LPR ROM
Modem failure
MODEM
OGM LOS
DISA OGM is lost
OPX power failure
OPX POW
SMDR
Printer is not connected
Description
Priority
Alarm LED
1
A
1
A
1
B
1
B
1
B
1
B
1
B
1
B
1
A
1
A
2
A
2
B
2
A
2
C
2
C
2
C
2
C
2
B
2
B
2
B
2
C
2
C
2
A