[Operation with external signals]
When using signals from an external control device to operate the inverter, take the measures shown in Figure 3.
Ex.) When using the potentiometer and forward run/reverse run terminals
[Accessories for countermeasure]
□ Recommended shield cable
If it is difficult to procure shielded cables, protect cables with conduit tubes.
□ [Note 1] Recommended shield : SUMITOMO 3M Limited, Electromagnetic wave guard shielding sleeve
□ EMI filter
□ Recommended ferrite core 1
Use the following, as required.
□ Recommended ferrite core
□ Zero-phase reactor
□ High-attenuation radio noise reduction filter
9.1.3 Low-voltage directive
The low-voltage directive provides for the safety of machines and systems. All Toshiba inverters are CE-marked in
accordance with the standard EN 50178 specified by the low-voltage directive, and can therefore be installed in
machines or systems and imported without a problem to European countries.
Applicable standard: EN50178
Pollution level:
Overvoltage category: 3
EN50178 applies to electrical equipment intended specially for use in the power installations, and sets out the
conditions to be observed for electric shock prevention when designing, testing, manufacturing and installing
electronic equipment for use in power installations.

9.1.4 Measures to be taken to satisfy the low-voltage directive

When incorporating the inverter into a machine or system, it is necessary to take the following measures so that the
inverter satisfies the low-voltage directive.
(1) Install the inverter in a cabinet and ground the inverter enclosure. When doing maintenance, be extremely careful
not to put your fingers into the inverter through a wiring hole and touch a charged part, which may occur depending
on the model and capacity of the inverter used.
Shielded cable or [Note 1]
: Showa electric Wire & Cable Co., LTD
Type : CV-S
Rating : 600V or less
Cross-sectional area : 2~1000mm
Type : DS-5, 7, 10, 14
: SCHAFFNER
Type : FN258/FN3258/FN359/FN3359/FS5992 series
: TDK Corporation
Type : ZCAT3035-1330
: NEC TOKIN Corporation
Type : ESD-R-47D-1
: Soshin Electric Co., Ltd.
Type : RC5078 or RC9129
: Soshin Electric Co., Ltd.
Type : NF series
Electronic equipment for use in power installations
2 (5.2.15.2)
200V class, 3.0mm (5.2.16.1)
400V class, 5.5mm (5.2.16.1)
I-7
Ferrite core 1
Fig. 3
2
E6581301
9