2) Automatic switching by means of switching frequencies (
Command selected
with
Command selected
with
A: If the frequency set with
B: If the frequency set with
Frequency setting signal
6
[ Parameter setting]
Title
A
is higher than that set with
is equal to or lower than that set with
Priority is given to
the command set
with
Function
Frequency setting mode selection 1
Frequency priority selection
Frequency setting mode selection 2
Speed command priority switching
frequency
Operation frequency
command
B
¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥
Priority is given to
the command set
.
with
Adjustment range
:VI/II (voltage/current input)
:RR/S4 (potentiometer/voltage input)
:RX (voltage input)
:Operation panel input enabled
(including LED/LCD option input)
:2-wire RS485 communication input
:4-wire RS485 communication input
:Communications option input
:Optional AI1 (differential current input)
:Optional AI2 (voltage/current input)
:Up/Down frequency
:Optional RP pulse input
:Optional high-speed pulse input
:Optional binary/BCD input
:
/
terminal switching
(input terminal function selection
)
:
/
frequency switching
(switching with
Same as
( ~
~
[Hz]
F-12
E6581301
= )
Priority is given to the
command set with
¥ ¥ ¥ ¥ ¥
Priority is given to the
command set with
.
Default setting
,
)
)
.
.