[21] Adjustment parameters [2/2]
Communi
Title
cation
Function
No.
0478
Optional AI2 input bias
0479
Optional AI2 input gain
PM motor constant 1 (d axis
0498
inductance)
PM motor constant 2 (q axis
0499
inductance)
*1: ⇒ Settings vary from unit to unit. Even if
[22] Acceleration/deceleration 2 [1/2]
Communi
Title
cation
Function
No.
0500
Acceleration time 2
0501
Deceleration time 2
Acceleration/deceleration 1
0502
pattern
Acceleration/deceleration 2
0503
pattern
Acceleration/deceleration 1, 2,
0504
3, 4 selection
Acceleration/deceleration
0505
switching frequency 1
Acceleration S-pattern lower
0506
limit adjustment
Acceleration S-pattern upper
0507
limit adjustment
Deceleration S-pattern lower
0508
limit adjustment
Deceleration S-pattern upper
0509
limit adjustment
0510
Acceleration time 3
0511
Deceleration time 3
Acceleration/ deceleration 3
0512
pattern
Acceleration/deceleration
0513
switching frequency 2
*1: Default values vary depending on the capacity. ⇒ See the table of K-46.
*2: Changing the parameter
enables to set to 0.01 sec. (adjustment range: 0.01~600.0 sec.).
Adjustment range
0~255
0~255
0~100%
0~100%
is set to
, no change is made to these values.
Adjustment range
0.1~6000 sec.
0.1~6000 sec.
0:Straight, 1:S-pattern 1, 2:S-pattern 2
0:Straight, 1:S-pattern 1, 2:S-pattern 2
1:Acceleration/deceleration 1
2:Acceleration/deceleration 2
3:Acceleration/deceleration 3
4:Acceleration/deceleration 4
0.0~
Hz
0~50%
0~50%
0~50%
0~50%
0.1~6000 sec.
0.1~6000 sec.
0:Straight, 1:S-pattern 1, 2:S-pattern 2
0.0~
Hz
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
*1
Enabled
●/●
1/1
*1
Enabled
●/●
1/1
40
Disabled
-
1/1
40
Disabled
-
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
0.1/0.1 *2
*1
Enabled
●/●
0.1/0.1 *2
*1
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
‚ P
Enabled
●/●
0. 1/0.01
0.0
Enabled
●/●
1/1
10
Enabled
●/●
1/1
10
Enabled
●/●
1/1
10
Enabled
●/●
1/1
10
Enabled
●/●
0.1/0.1 *2
*1
Enabled
●/●
0.1/0.1 *2
*1
Enabled
●/●
1/1
0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
PM
Torque
V/f Constant Reference
control
control
●/●
6. 28
●/●
6. 28
-
-
6. 29
-
-
6. 29
PM
Torque
V/f Constant Reference
control
control
-
6. 30. 1
-
6. 30. 1
-
6. 30. 1
-
6. 30. 1
-
6. 30. 1
-
6. 30. 1
-
6. 30. 1
-
6. 30. 1
-
6. 30. 1
-
6. 30. 1
-
6. 30. 1
-
6. 30. 1
-
6. 30. 1
-
6. 30. 1