For a crane/hoist, an elevator application, as lifted
up and down at controlled speeds, the direction of
rotation is frequently reversed. In such cases, the
load can be started smoothly, by adding load
torque into the torque reference equivalent to the
additional torque, when starting acceleration after
releasing the brake.
[Selection of external signals]
RR/S4-CC – 0~10V
Voltage signals
RX-CC – 0~±10V
VI/II-CC – 0~10V
Current signals
VI/II-CC – 4(0)~20mA

2) Selection of tension torque bias input and load sharing gain input

Load sharing gain
Torque reference
Tension torque bias
[Parameter setting]
Title
Function
Tension torque bias input
selection
Control panel tension torque bias
Load sharing gain selection
Control panel load sharing gain
[Selection of external signals]
Voltage signals
Current signals
Tension torque bias
as additional torque
(0~250%)
(-250~250%)
(0~250%)
(0~250%)
×
:Disabled
:VI/II (voltage/current input)
:RR/S4 (potentiometer/voltage input)
:RX (voltage input)
:Operation panel input enabled (including
LED/LCD option input)
:2-wire RS485 input enabled
:4-wire RS485 input enabled
:Communication option input enabled
:Optional AI1 (Differential current input)
:Disabled
:VI/II (voltage/current input)
:RR/S4 (potentiometer/voltage input)
:RX (voltage input)
:Operation panel input enabled (including
LED/LCD option input)
:2-wire RS485 input enabled
:4-wire RS485 input enabled
:Communication option input enabled
:Optional AI1 (Differential current input)
~
RR/S4-CC – 0~10V
(0~250%)
RX-CC – 0~±10V
(-250~250%)
VI/II-CC – 0~10V
(0~250%)
VI/II-CC – 4(0)20m
(0~250%)
F-41
Reverse run
Forward run
Additional torque
(fixed direction)
+
Torque command
+
+
Adjustment range
~
%
%
,
E6581301