Selecting Control Mode - Toshiba TOSVERT VF-AS1 Instruction Manual

The new high-performance inverter tosvert
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

5.6

Selecting control mode

: V/f control mode selection
• Function
With "VF-AS1," the V/f controls shown below can be selected.
0: Constant torque characteristics
1: Voltage decrease curve
2: Automatic torque boost *1
3: Sensorless vector control 1 *1
4: Sensorless vector control 2
5: V/f 5-point setting
6: PM control
7: PG feedback vector control 1
8: PG feedback vector control 2
(*1) "Automatic control" parameter automatically sets this parameter and auto-tuning 1 at a time.
[Parameter setting]
Title
V/f control mode selection
1) Constant torque characteristics (Normal way of use)
Setting of V/f control mode selection
This is applied to loads with equipment like conveyors and cranes that require the same torque at low speeds as at
rated speeds.
Base frequency voltage 1
[V]/[%]
* To increase the torque further, increase the setting value of the manual torque boost parameter
⇒ For more details, refer to Section 5.7.
Function
: Constant torque characteristics
: Voltage decrease curve
: Automatic torque boost
: Sensorless vector control 1
: Sensorless vector control 2
: V/f 5-point setting
: PM control
: PG feedback vector control 1
: PG feedback vector control 2
0
Base frequency
E-11
Adjustment range
=
(Constant torque characteristics)
Output frequency [Hz]
E6581301
Default setting
5
.