Following parameters are designed considering maintenance that they cannot be reset to the factory default setting
even if you set the parameter
even if their settings are different from their default settings. So please be careful.
Title
History function
FM terminal meter selection
FM terminal meter adjustment
AM terminal meter selection
AM terminal meter adjustment
Analog VI/VII voltage/current switching
Analog AI2 (optional circuit board)
voltage/current switching
VI/II input bias
VI/II input gain
RR/S4 input bias
RR/S4 input gain
RX input bias
RX input gain
5
Optional AI1 input bias
Optional AI1 input gain
Trip clear (
Setting
* (The parameter does not change.)
Cumulative operation time clear (
Setting
Initialization of type information (
When a trip occurs because of a type error (
function is used to reformat a control circuit board to adapt it to an inverter, for example, when a circuit board is
removed from an inverter to use another inverter for maintenance or for other reasons. This setting clears all type
data stored in the inverter.
Save user-defined parameters (
Setting
Reset of user-defined parameters (
Setting
* The above settings
Cumulative fan operation time clear (
Setting
when replacing the cooling fan, and so on.
Acceleration/deceleration time setting: 0.01 to 600.0 sec. (
When
Acceleration/deceleration time setting: 0.1 to 6000 sec. (
When
= )
to
resets all parameters except the following to their default settings.
). Note that this setting also clears all trip history records. Trip history data will be cleared at this time.
at
. Following parameters are not displayed on the user parameter group
Function
= )
to
initializes the past four sets of recorded trip history data.
to
resets the cumulative operation time monitor to the initial value (0 [zero] time).
to
causes all the current parameter settings to be stored individually.
to
returns all parameters to the settings saved by setting the parameter
and
allows you to have your own default parameter settings.
to
resets the cumulative fan operation time to the initial value (0 [zero] time). Set this parameter
is set to
, the acceleration/deceleration time can be set within a range of 0.01 to 600.0 sec.
is set to
, the acceleration/deceleration time can be set within a range of 0.1 to 6000 sec.
is displayed for a while, then switches back to the original display (
Title
Optional AI2 input bias
Optional AI2 input gain
Logic output/pulse train output selection (OUT1)
MON1 terminal meter selection
MON1 terminal meter adjustment
MON2 terminal meter selection
MON2 terminal meter adjustment
FM voltage/current output switching
MON1 voltage/current output switching
MON2 voltage/current output switching
Quick registration parameter 1~32
Free notes
Network option reset setting
= )
= )
is displayed), you can clear the trip by setting
= )
= )
= )
E-42
E6581301
Function
to
. This
= .
=
)
=
)

Advertisement

Table of Contents
loading

Table of Contents