Toshiba TOSVERT VF-AS1 Instruction Manual page 26

The new high-performance inverter tosvert
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

For 200V/0.4kW to 200V/7.5kW models and 400V/0.75kW to 400V/11kW models, cut off the tabs (part A in the figure
below) on the main circuit terminal board if necessary for connecting the cables from the power supply.
200V-0.4kW~3.7/4.0kW
400V-0.75kW~3.7/4.0kW
1
Front cover
To wire the main circuit terminal board for models 200V-18.5kW or more and 400V-22kW or more, remove the front
cover.
Remove the screw
Control circuit terminal board cover
To wire the control circuit terminal board, open the control circuit terminal board cover in line with the steps given
below.
(1)
Control circuit terminal board
A
Open the control circuit terminal board cover.
* To open the cover, lift it with your finger
placed at the
part on the right side of the
cover. • @
200V-5.5kW~7.5kW
400V-5.5kW~11kW
Main circuit terminal board
(2)
(1)
Remove the terminal board, if necessary.
* To do so, open the main circuit terminal
board cover, loosen the screws that fix the
terminal board, using a (-) screwdriver or
torx (T20H) screwdriver, placed your
finger on part
terminal board.
A-10
E6581301
A
(2)
(3)
and pull out the
• @

Advertisement

Table of Contents
loading

Table of Contents