Frequency [Hz]
Torque [N·m]
Torque limit level
Mechanical brake
(2)
= (In sync with min. time)
The operation frequency keeps increasing, even if the torque limit function is activated.
In this control mode, the actual speed is kept in sync with the operation frequency, while torque is held at a limit
level when it decreases as a result of the release of the mechanical brake. The use of this function prevents the
load from failing and improves the motor's response during inching operation.
Frequency [Hz]
Torque [N·m]
Torque limit level
Mechanical brake
Operation frequency
If the torque limit function
is not activated
ON
OFF
(released)
Operation frequency
Torque is held at a limit level even
after the mechanical brake is released.
ON
OFF
(released)
F-45
Actual speed
Time [s]
Time [s]
Time [s]
Actual speed
(Acceleration rates vary depending
on the torque limit level.)
Time [s]
Time [s]
Time [s]
E6581301