[14] Functions for lift [1/2]
Communi
Title
cation
Function
No.
0324
Drooping output filter
Light-load high-speed operation
0328
selection
0329
Light-load high-speed learning function
Automatic light-load high-speed
0330
operation frequency
Light-load high-speed operation
0331
switching lower limit frequency
Light-load high-speed operation
0332
load waiting time
Light-load high-speed operation
0333
load detection time
Light-load high-speed operation
0334
heavy load detection time
Switching load torque during
0335
power running
0336
Heavy-load torque during power running -250~250%
Heavy-load torque during
0337
constant power running
Switching load torque during
0338
regenerative braking
0341
Braking mode selection
0342
Load portion torque input selection
Hoisting torque bias input (valid
0343
only when
= )
0344
Lowering torque bias multiplier 0~100%
0345
Brake release time
0346
Creeping frequency
0347
Creeping time
0348
Braking time learning function
*1: ⇒ For details, refer to Instruction Manual (E6581327) specified in Section 6.41. *2: Inverter with a model number ending with -WN: 60.0 -WP: 50.0
Adjustment range
0.1~200.0 rad/s (Enabled if
=3, 4, 7 or 8)
0:Deselect
1:High-speed operation speed set automatically
(Power running at F command: Increase)
2:High-speed operation speed set automatically
(Power running at R command: Increase)
3:High-speed operation speed set with
(Power running at F command: Increase)
4:High-speed operation speed set with
(Power running at R command: Increase)
0:No learning, 1:Forward run learning
2:Reverse run learning
30.0~
Hz
30.0~
Hz
0.0~10.0 sec.
0.0~10.0 sec.
0.0~10.0 sec.
-250~250%
-250~250%
-250~250%
0:Deselect, 1:Forward winding up
2:Reverse winding up
3:Horizontal operation (counter weight)
0:Disabled, 1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4:
enabled
5:2-wire RS485 communication input
6:4-wire RS485 communication input
7:Communications option input enabled
8:Optional AI1 (differential current input)
-250~250%
0.00~2.50 sec.
~20.0 Hz
0.0~2.50 sec.
0:Deselect, 1: Learning (0 after adjustment)
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
0.1/0.1
100.0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Disabled
●/●
0.1/0.01
*2
Disabled
●/●
0.1/0.01
40.0
Enabled
●/●
0.1/0.1
0.5
Enabled
●/●
0.1/0.1
1.0
Enabled
●/●
0.1/0.1
0.5
Enabled
●/●
1/0.01
50
Enabled
●/●
1/0.01
100
Enabled
●/●
1/0.01
50
Enabled
●/●
1/0.01
50
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/0.01
100
Enabled
●/●
1/0.01
100
Enabled
●/●
0.01/0.01
0.05
Enabled
●/●
0.1/0.01
3.0
Enabled
●/●
0.01/0.01
0.10
Disabled
●/●
1/1
0
Enabled
●/●
PM
Torque
V/f
Reference
control
control
-
-
-
6. 15
-
*1
-
-
-
*1
-
*1
-
*1
-
*1
-
*1
-
*1
-
*1
-
*1
-
*1
-
*1
-
-
-
6. 17
-
-
-
6. 17
-
-
-
6. 17
-
-
-
6. 17
-
-
-
6. 17
-
-
-
6. 17
-
-
-
6. 17
-
-
-
6. 17

Advertisement