Measures To Satisfy The Emc Directive - Toshiba TOSVERT VF-nC3 Instruction Manual

Hide thumbs Also See for TOSVERT VF-nC3:
Table of Contents

Advertisement

Category
Emission
Immunity
9.1.2
This subsection explains what measures must be taken to satisfy the EMC directive.
(1) Insert a recommended EMI filter (Table 2) on the input side of the inverter to reduce and transmission noise
and radiation noise from input cables.
In the combinations listed in Table 2, Inverters are tested in these combinations to see if they comply with
transmission noise standards.
Table 2 lists noise filters recommended for the inverters.
Three-phase 240V class
9
Inverter type
VFNC3-2001P
VFNC3-2002P
VFNC3-2004P
VFNC3-2007P
VFNC3-2015P
VFNC3-2022P
Table 1 EMC standards
Subcategory
Radiation noise
Transmission noise
Static discharge
Radioactive radio-frequency
magnetic contactor field
First transient burst
Lightning surge
Radio-frequency
induction/transmission interference
Voltage dip/Interruption of power

Measures to satisfy the EMC directive

Table 2 Combinations of inverter and EMI filter
Combination of inverter and filter
Transmission noise
IEC61800-3 Category C1
Applicable filters
(Length of motor connecting cable: Max.
5 m, PWM carrier frequency : 4 to 12kHz)
Product
standards
IEC 61800-3
(Length of motor connecting cable: Max.
20 m, PWM carrier frequency : 4 to 12kHz)
-
-
-
-
EMFA2015Z
EMFA2015Z
I-2
E6581595
Test standard
CISPR11(EN55011)
CISPR11(EN55011)
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-11
Transmission noise
IEC61800-3 Category C2
Applicable filters
EMFA2006Z
EMFA2006Z
EMFA2006Z
EMFA2006Z