Searching For All Reset Parameters And Changing Their Settings - Toshiba TOSVERT VF-AS1 Instruction Manual

The new high-performance inverter tosvert
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

5.21

Searching for all reset parameters and changing their settings

: Automatic edit function
• Function
Automatically searches for only those parameters that are programmed with values different from the
standard default setting and displays them in the user parameter group
changed within this group.
Note 1: If you reset a parameter to its factory default, the parameter will no longer appear in
Note 2: It may take several seconds to display changed parameters because all data stored in the user parameter
group
press the
MODE
Note 3: Parameters which cannot be reset to the default setting after setting
• Ë
Refer to Section 5.20 for details.
How to search and reprogram parameters
The operations of search and resetting of parameters are as follows.
Key operated
MODE
ENT
ENT
or
ENT
ENT
(
(
MODE
MODE
is checked against the factory default settings. To cancel the parameter group search in process,
key.
LED display
Displays the operation frequency (operation stopped).
(When standard monitor display selection
frequency])
The first basic parameter "History function (
Press
Press the ENTER key to enable the user parameter automatic edit
function.
Searches for parameters that are different in value from the standard
default setting and displays those parameters. Press the ENTER key
or the
to search for parameters in reverse direction.)
Press the ENTER key to display the set value.
Press the
Press the ENTER key to save the changed value. The parameter
name and the programmed value will flash on and off alternately.
Use the same steps as those given above to display parameters that
)
(
)
you want to search for or change setting with the
)
When
A search can be canceled by pressing the MODE key. Press the key
Parameter display
once while the search is underway to return to the display of
parameter setting mode.
After that you can press the MODE key to return to the status monitor
mode or the standard monitor mode (display of operation frequency).
Operation
or
key to select
key to change the parameter displayed. ( Press the
key and
key to change set value.
appears again, the search is ended.
E-43
E6581301
. Parameter setting can also be
.
to
are not displayed.
=
[Output
)" is displayed.
.
key and
key.
5
key

Advertisement

Table of Contents
loading

Table of Contents