In the web configurator, click Configuration > PBX > Outbound Line Management > LCR >
1
Add. Enter a name and description for the dialing rule (the LCR is named ISDN_call in this
example). Select the outbound line group from the pool column that you want to add to this LCR (in
our example this is BRI1 as configured in
move them to the Selected column. Click the Add icon to configure a dial condition.
The Dial Condition screen appears.
2
• Type 800 followed by a period (.) in the Dial Condition field. This means that this LCR will be
used when callers dial any number that begins with 800. The period (.) is a wildcard character,
meaning anything can follow the 800.
• Leave the offset value empty. In our example, we do not need to configure the offset value.
See
Figure 124 on page 156
• Select the dial condition parameter entry and click Number Pattern Test to check whether a
number dialed from one of the extensions meets the criteria specified in the Dial Condition
field. In the pop-up window, type a number in the Number Pattern Test field and click the
right arrow button. An O appears, if the number you typed matches the dial condition. An X
appears, if the number you typed does not match the dial condition. In our example, we tested
the number 8005555555 to see if it matches our dial condition.
ISG50 User's Guide
Section 8.5.1 on page
for an example.
Chapter 8 PBX Tutorials
155), then click the Right icon to
157