Setting Motor Parameters - Omron SYSDRIVE 3G3FV User Manual

High-function general-purpose inverter
Table of Contents

Advertisement

Advanced Operation
Increase the setting in C7-02 if vibration occurs when operating with a light load.
(If the setting is increased too much, the current can fall to the point where stalling occurs.)
Decrease the setting in C7-02 if stalling occurs.
Disable the hunting-prevention function (C7-01 = 0) if high responsiveness is more important than
suppressing vibration.

6-4-4 Setting Motor Parameters

The motor parameters other than the V/f pattern parameters are described below:
Calculate the rated slip (E2-02) from the value shown on the motor's nameplate with the following equa-
tion and set this value.
Rated slip = rated frequency (Hz) – rated speed (r/min)
Set the no-load current (E2-03) at the rated voltage and rated frequency. Normally this value isn't shown
on the motor's nameplate, so it might be necessary to contact the motor manufacturer.
Parameter
Display name
p y
number
E2-02
Motor Rated Slip
E2-03
No-Load Current
Note 1. The default setting depends upon the type of Inverter.
(The table shows the default settings for 200-V class, 0.4-kW Inverters.)
Note 2. The setting range is between 0.00 and 0.1 less than the Inverter's rated current.
Note 3. These settings are used as reference values for the motor slip compensation function.
Set the motor's terminal resistance (phase to phase) in parameter E2-05. Normally this value isn't
shown on the motor's nameplate, so it might be necessary to contact the motor manufacturer.
Parameter
Display name
p y
number
E2-05
Term Resistance 0.000 to 65.000
Note 1. The default setting depends upon the type of Inverter.
(The table shows the default settings for 200-V class, 0.4-kW Inverters.)
Note 2. This setting is used as a reference value for the torque compensation function.
Parameter
Display name
p y
number
E2-10
Tcomp Iron Loss
Note 1. The default setting varies with the Inverter's capacity. The above setting applies to 200-V
class, 0.4-kW Inverters.
Note 2. Set the iron core loss in 1-W increments. The default setting does not normally need to be
changed.
Note 3. The set value is used as the reference value for the torque compensation function.
Setting range Units
g
g
0.00 to 20.00
Hz
0.00 to 2.90
A
(see note 2)
Setting range
g
g
Units Default
Setting range Units
g
g
0 to 65535
W
number of poles/120
Valid access levels
Default
setting*
V/f
V/f with
Control
2.90
Advanced
1.20
Valid access levels
setting
V/f
V/f with
Control
PG
9.842
Advanced
Valid access levels
Default
setting*
V/f
V/f with
Control
14
Advanced
Chapter 6
Open Loop
Flux
PG
Vector
Vector
Quick Start, Basic,
,
or Advanced
Open Loop
Flux
Vector
Vector
Open Loop
Flux
PG
Vector
Vector
Not applicable.
,
6-39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents