Motor Constant Parameter Lists - Omron SYSDRIVE 3G3FV User Manual

High-function general-purpose inverter
Table of Contents

Advertisement

Parameter Lists
Para
Para
Name
meter
meter
Display
No.
No.
name
d5-03
Sets the speed limit command
Speed limit
selection
method for the torque control
mode.
1: The analog input limit from
an analog frequency
an analog frequency
Speed Limit
reference terminal
Sel
(terminals 13 and 14.)
2: Limited to d5-04 parameter
setting values.
d5-04
Speed limit
Sets the speed limit during
torque control as a percentage
of the maximum frequency.
Note: This function is enabled
Speed Lmt
Value
d5-05
Sets the speed limit bias as a
Speed limit
bias
percentage of the maximum
frequency.
Note: Bias is given to the speci
Note: Bias is given to the speci-
Speed Lmt
Bias
d5-06
Speed/
Sets the delay time from
inputting the multi-function input
torque con-
"speed/torque control change"
trol switch-
ing timer.
(from ON to OFF or OFF to ON)
until the control is actually
changed, in ms units.
Note: This function is enabled
Ref Hold
Time

7-2-4 Motor Constant Parameter Lists

H V/f Pattern: E1
Name
Para
meter
meter
Display
No.
name
E1-01
Sets the Inverter input voltage in
Input
voltage
units of 1 V.
setting
Note: This setting is used as the
Input
Voltage
7-24
Description
Description
1, 2
–120 to
+120
when d5-03 is set to 2.
when d5 03 is set to 2
Directions are as follows.
+: operation command
direction
–: operation command
opposite direction
0 to
120
fied speed limit. It can be
used to adjust the margin
for the speed limit.
0 to
1000
when the multi-function
input "speed/torque con-
trol change" is set. In the
g
speed/torque control
speed/torque control
switching timer, the three
analog inputs hold the
values of when the
"speed/torque control
change" changes. Always
be sure to allow time for
this process to finish com-
pletely.
Description
155 to
255
(see
note 1)
note 1)
reference value for func
reference value for func-
tions such as the protec-
tion functions.
Setting
Setting
Default
Default
Chan-
Chan-
range
range
setting
setting
ges
ges
during
during
opera-
opera-
tion
tion
1
NO
0
NO
10
NO
0
NO
Setting
Default
Chan-
range
range
setting
setting
ges
ges
during
opera-
tion
200
NO
(see
note 1)
Chapter 7
Control mode
V/f
V/f
Open
control
with
loop
PG
vector
X
X
X
X
X
X
X
X
X
X
X
X
Control mode
V/f
V/f
Open
control
with
loop
PG
vector
Q
Q
Q
Page
Page
Flux
vector
A
6-22
A
6-23
A
6-24
A
6-28
Page
Flux
vector
Q
5-20,
5-23,
5-35,
5-44
5-44