Preparing for Operation
The following restrictions apply to setting/displaying parameters when the access level is set to the user
level.
Mode
Operation
The Quick-start level parameters can be displayed.
Initialize
The Quick-start level parameters can be set or displayed.
Program
Only the parameters specified in A2-01 through A2-32 can be set or displayed.
Auto-tuning
The parameters cannot be displayed.
Modified constants The parameters cannot be displayed.
Setting Example
The following example shows how to specify parameter C1-01 (Acceleration time 1) in user parameter
A2-01 and set the access level to the user level.
Key sequence
2 times
2 times
7 times
2 times
2 times
Accessible parameters
Display
Displays operation mode.
Displays initialize mode.
Puts the Unit in initialize mode.
(Select Language display)
Displays the User Parameters display.
Displays the parameter setting for A2-01.
Selects the parameter so that the leading digit flashes.
(The digit that can be changed flashes.)
Sets the first digit to "C."
(At this point the other digits will be displayed.)
Moves the cursor to the third digit.
Sets the last digits to "08."
Writes the new setting.
Returns to the parameter setting for A2-01.
Returns to the User Parameters display.
Displays the Access Level display.
Displays the parameter setting for A1-01.
Changes the setting to "User Level."
Writes the new setting.
Returns to the Access Level display.
Returns to the initialize mode display.
Chapter 3
Explanation
3-23