Omron SYSDRIVE 3G3FV User Manual page 259

High-function general-purpose inverter
Table of Contents

Advertisement

Advanced Operation
S Acceleration/Deceleration Ramp Hold (Setting: A)
S UP and DOWN Commands (Settings: 10 and 11)
S Trim Control Increase and Decrease (Settings: 1C and 1D)
S Analog Frequency Reference Sample/Hold (Setting: 1E)
Analog Frequency Reference Sample/Hold (Setting: 1E)
This function retains the analog input in the Inverter.
If the analog frequency reference sample/hold input is ON for 100 ms continuously, the analog value
that is input 100 ms after the analog frequency reference sample/hold input turns ON will be sampled
and retained.
The retained analog value will be kept on hold until the next sampling period.
All the following analog inputs are applicable.
Frequency reference input (voltage): Pin 13
Frequency reference input (current): Pin 14
Multi-function analog input: Pin 16
Analog Input Cards: 3G3IV-PAI14U/3G3IV-PAI14B
Note Select and set one of the following functions for multi-function input. Do not set more than one of
them, otherwise a setting error (OPE3) will result.
S Acceleration/Deceleration Ramp Hold (Setting: A)
S UP and DOWN Commands (Settings: 10 and 11)
S Trim Control Increase and Decrease (Settings: 1C and 1D)
S Analog Frequency Reference Sample/Hold (Setting: 1E)
Sample/hold
command
Analog output and
frequency refer-
ence (hold value)
Analog input
Frequency reference (hold value)
Chapter 6