Application Parameters (B) - Omron SYSDRIVE 3G3FV User Manual

High-function general-purpose inverter
Table of Contents

Advertisement

Advanced Operation
Group
Group
Function
Function
Terminal
e
a
H1
Digital Inputs
H2
Digital Outputs
H3
Analog Inputs
H4
Analog Outputs
H5
Serial Com Setup
Protection
o ec o
L1
Motor Overload
L2
PwrLoss Ridethru
L3
Stall Prevention
L4
Ref Detection
L5
Fault Restart
L6
Torque Detection
L7
Torque Limit
L8
Hdwe Protection
O e a o
Operator
o1
Monitor Select
o2
Key Selections

6-5-2 Application Parameters (b)

H Setting Operation Source Selection (b1)
The input methods of parameters or frequency references and the operation methods of the run com-
mand can be set in the Inverter in operation mode. In addition, the following advanced functions are
available.
The run command already set in the Inverter can be disabled or enabled when switching the Inverter to
local mode from remote mode.
The run command already set in the Inverter in any mode other than drive mode can be disabled or
enabled.
Set the parameter according to the application.
Parameter
Display name
p y
number
b1-07
LOC/REM RUN
Set
Explanation of Settings
Setting
0
The run command already set is disabled (when the Inverter is switched to local mode
from remote mode. The Inverter will start operating with the run command input again.)
1
The run command already set is enabled (and the Inverter will start operating according
to the present run command when the Inverter is switched to local mode from remote
mode).
Note If parameter b1-07 (LOC/REM RUN Sel) is set to 1, the run command will not be ignored. In this
case, an Inverter may start operating immediately when switched to remote mode from local
mode. Take necessary measures for safety.
Comments
Comments
S Function selection for multi-function inputs
S Function selection for multi-function outputs
S Adjustment/function selection for external analog in-
puts
S Adjustment/function selection for multi-function analog
outputs
Not Used. (Do not change this setting.)
S Sets electrical/thermal functions that protect the motor.
S Selects the power-loss processing method.
S Accel/Decel stall prevention settings and selection
S Frequency detection settings and selection
S Fault restart function settings
S Sets overtorque detection functions 1 and 2
Torque limit settings
S Hardware overheating and phase loss protection set-
tings
S Selects the Operator's display and setting methods.
S Operator's key function selection and other parame-
ters
Setting
g
Units
Default
range
setting
0, 1
---
0
OK
OK
OK
OK
---
OK
OK
OK
OK
OK
OK
---
OK
OK
OK
Valid access levels
V/f
V/f with
Control
PG
Advanced
Description
Chapter 6
Control mode
V/f
V/f
Open-loop
Flux
w/PG
Vector
Vector
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
---
---
---
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
---
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
Open Loop
Flux
Vector
Vector
6-41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents