Omron SYSDRIVE 3G3FV User Manual page 261

High-function general-purpose inverter
Table of Contents

Advertisement

Advanced Operation
Unlike other parameter settings, the external fault settings have an input procedure, as shown in the
following diagrams.
1. When setting an external fault function, press the Enter Key when "External Fault" is displayed to
bring up the "Input Level" display.
2. Press the Increment Key to switch displays as follows:
"Detection Method"
3. Press the Enter Key at the desired parameter to select that parameter. At this point, the Increment
and Decrement Keys can be pressed to scroll through the available settings for the selected param-
eter. Press the Enter Key to select the displayed parameter setting.
(Press the Escape Key to cancel the operation without changing the parameter setting.)
Input level
Detection method
Operation selection
External Fault
"Operation Selection"
N.O. Contact
N.C. Contact
Always
During operation
Ramp to Stop
Coast to Stop
Emergency Stop
Continue operation
Input level
Detection method
Operation
Selection
"Input Method"
Set parameter
Set parameter
Set parameter
Chapter 6
6-87