Software Ver. Vsg101114 - Omron SYSDRIVE 3G3FV User Manual

High-function general-purpose inverter
Table of Contents

Advertisement

Introduction
New Parameter Default Setting
Parameter
number
L2-04
Voltage restart time

1-3-4 Software Ver. VSG101114

H PG Speed Deviation Detection Function Upgrade (F1-04)
This function has been changed so that the conditions can be selected for speed deviation (DEV) detec-
tion. Either of the following two conditions can be selected by means of an F1-04 parameter setting.
Detect only when the frequency reference matches the output frequency (within the range set in
L4-02).
Detect only when the frequency reference matches the PG feedback speed (within the range set
in L4-02).
Parameter name
Applicable
Previous setting
Inverters
Inverters of
0.6 s
55 kW or larger
Chapter 1
New setting
range
range
1.0 s
1-17