Introduction
1-3

New Functions

The following software versions have been implemented for the 3G3FV Series to add
and upgrade functions.
August 1996: Software Ver. VSG101032 (S1032)
April 1997:
Sept. 1998:
Sept. 1999:
Sept. 2000:
The software version can be confirmed using the 5-digit number display for the FLASH
ID for U1-14.
This section describes the new functions and improvements for each software version.
Refer to Chapter 5 Basic Operation and Chapter 6 Advance Operation .

1-3-1 Software Ver. VSG101040

H CompoBus/D (DeviceNet) Communications Card
The CompoBus/D Communications Card can be used to connect the Inverter to a DeviceNet network.
The following function additions and improvements were made to support this new functionality.
CompoBus/D Addition to the Frequency Reference Selection (Parameter b1-01)
A function was added to Frequency Reference Selection so that the Inverter frequency reference can
be input via DeviceNet communications.
CompoBus/D Addition to the Run Source Selection (Parameter b1-02)
A function was added to Run Source Selection so that the Inverter run command can be input via Devi-
ceNet communications.
Communications External Fault Input (Parameters F9-01 to F9-03)
A function was added to support an external fault input from DeviceNet communications to stop the
Inverter when an error occurs. Sequence settings and operation designation for errors for the commu-
nications external fault input have been added.
H Two-motor Switching Control
A function was added to enable switching control between two motors using one Inverter. The following
function additions were made to support this new functionality.
Control Mode Setting Second Motor (Parameter E3-01)
A control mode setting was added so that the second motor can be set to a different mode.
Note The control mode setting was limited to 0 (
was changed in system version VSG101043 to support all control modes 0 to 3.
V/f Pattern Settings for Second Motor (Parameters E4-01 to E4-06)
V/f pattern settings were added so that the second motor can be set to a different pattern.
Software Ver. VSG101040 (S1040)
Software Ver. VSG101043 (S1043)
Software Ver. VSG101113 (S1113)
Software Ver. VSG101114 (S1114)
V/f control without PG) or 2 (open-loop vector control), but