Parameter Lists
Para
Para
Name
meter
meter
Display
No.
No.
name
L6-03
Sets the torque detection time in
Torque
detection
1-second units.
time 1
Torq Det 1
Time
L6-04
Torque
Setting procedure is the same
as for "Torque detection
detection
selection 2
selection 1" (L6-01 to L6-03.)
The following outputs are
Torq Det 2
possible:
Sel
T
Torque detection selection 1:
L6-05
Torque
Multi-function output "Torque
detection
detection selection 1" NO/NC
level 2
Torque detection selection 2:
Torque detection selection 2:
Torq Det 2
Multi-function output "Torque
Lvl
detection selection 2 NO/NC
detection selection 2" NO/NC
L6-06
Torque
detection
time 2
Torq Det 2
Time
H Torque Limit: L7
Name
Para
meter
meter
Display
No.
name
L7-01
Sets the torque limit value as a
Forward
torque limit
percentage of the motor rated
torque. Four individual regions
t
Torq Limit
can be set.
Fwd
L7-02
Reverse
Reverse
torque limit
L7 04
L7-04
Torq Limit
Regenerative
Rev
state
state
L7-03
Forward re-
generative
torque limit
L7-02
L7-02
Torq Lmt
Fwd Rgn
L7-04
Reverse re-
generative
torque limit
Torq Lmt
Rev Rgn
H Hardware Protection: L8
Name
Para
meter
meter
Display
No.
name
L8-01
0: Disabled (Braking resistor is
DB resistor
protection
not used or the Braking
Resistor Unit is used)
Resistor Unit is used)
DB
1: Enabled (Protects the
Resistor
braking resistor from
Prot
overheating)
Description
Description
Setting
Setting
range
range
0.0 to
10.0
0 to 4
(
)
d t
ti
l
ti
1
0 to
300
0.0 to
10.0
Description
Setting
range
range
0 to
g
300
F
i di id
l
i
O
Output torque
0 to
Forward side
300
L7-01
L7-01
Motor
speed
s eed
Regenerative
0 to
state
300
L7-03
03
Reverse side
0 to
300
Description
Setting
range
range
0, 1
Default
Default
Chan-
Chan-
setting
setting
ges
ges
V/f
during
during
control
opera-
opera-
tion
tion
0.1
NO
B
0
NO
A
150
NO
A
0.1
NO
A
Default
Chan-
setting
setting
ges
ges
V/f
during
control
opera-
tion
200
NO
X
200
NO
X
200
NO
X
200
NO
X
Default
Chan-
setting
setting
ges
ges
V/f
during
control
opera-
tion
0
NO
B
Chapter 7
Control mode
V/f
Open
Flux
with
loop
vector
PG
vector
B
B
B
6-108
A
A
A
6-108
A
A
A
6-108
A
A
A
6-108
Control mode
V/f
Open
Flux
with
loop
vector
PG
vector
X
B
B
6-3,
6-29
X
B
B
6-3,
6-29
X
B
B
6-3,
6-29
X
B
B
6-3,
6-29
Control mode
V/f
Open
Flux
with
loop
vector
PG
vector
B
B
B
6-109
Page
Page
Page
Page
7-49