Field
MAC Address
State
Time
MAC Status

display cfd service-instance

Syntax
display cfd service-instance [ instance-id ] [ | { begin | exclude | include } regular-expression ]
View
Any view
Default level
1: Monitor level
Parameters
instance-id: Service instance ID, ranging from 1 to 32767.
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see Fundamentals Configuration Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Description
Use display cfd service-instance to display the configuration information of a service instance.
Without specifying the service instance ID, the command will display the configuration information of all
service instances.
Examples
# Display the configuration information of all service instances.
<Sysname> display cfd service-instance
Description
MAC address of the remote MEP device.
A hyphen (-) means not supported.
Running state of the remote MEP, which can be OK or FAILED.
Time when the remote MEP entered the FAILED or OK state for the last time.
State of the port indicated by the last CCM received from the remote MEP:
UP—The interface is ready to pass packets.
DOWN—The interface cannot pass packets.
TESTING—The interface is in some test mode.
UNKNOWN—The interface status cannot be determined for some reason.
DORMANT—The interface is not in a state to pass packets but is in a
pending state, waiting for some external event.
NOT-PRESENT—Some component of the interface is missing.
LLD—The interface is down because of the state of the lower layer
interfaces.
A hyphen (-) means not supported.
45