Oam Errored-Frame-Seconds Threshold; Oam Errored-Symbol Period - HP 6125G Command Reference Manual

High availability command reference
Hide thumbs Also See for 6125G:
Table of Contents

Advertisement

Use undo oam errored-frame-seconds period to restore the default.
By default, the errored frame seconds event detection interval is 60 seconds.
Related commands: oam errored-frame-seconds threshold, display oam link-event, and display oam
configuration.
Examples
# Set the errored frame seconds event detection interval to 100 seconds.
<Sysname> system-view
[Sysname] oam errored-frame-seconds period 100

oam errored-frame-seconds threshold

Syntax
oam errored-frame-seconds threshold threshold-value
undo oam errored-frame-seconds threshold
View
System view
Default level
2: System level
Parameters
threshold-value: Errored frame seconds event triggering threshold, ranging from 0 to 900.
Description
Use oam errored-frame-seconds threshold to set the errored frame seconds event triggering threshold.
Use undo oam errored-frame-seconds threshold to restore the default.
By default, the errored frame seconds event triggering threshold is 1.
Related commands: oam errored-frame-seconds period, display oam link-event, and display oam
configuration.
Examples
# Set the errored frame seconds event triggering threshold to 100.
<Sysname> system-view
[Sysname] oam errored-frame-seconds threshold 100

oam errored-symbol period

Syntax
oam errored-symbol period period-value
undo oam errored-symbol period
View
System view
Default level
2: System level
13