HP 6125G Command Reference Manual page 10

High availability command reference
Hide thumbs Also See for 6125G:
Table of Contents

Advertisement

Parameters
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see Fundamentals Configuration Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Description
Use display oam configuration to display global Ethernet OAM configuration, including the periods and
thresholds for Ethernet OAM link error event detection.
Related commands: oam errored-symbol period, oam errored-symbol threshold, oam errored-frame
period, oam errored-frame threshold, oam errored-frame-period period, oam errored-frame-period
threshold, oam errored-frame-seconds period, and oam errored-frame-seconds threshold.
Examples
# Display global Ethernet OAM configuration.
<Sysname> display oam configuration
Configuration of the link event window/threshold :
--------------------------------------------------------------------------
Errored-symbol Event period(in seconds)
Errored-symbol Event threshold
Errored-frame Event period(in seconds)
Errored-frame Event threshold
Errored-frame-period Event period(in ms)
Errored-frame-period Event threshold
Errored-frame-seconds Event period(in seconds)
Errored-frame-seconds Event threshold
Table 3 Command output
Field
Configuration of the link event
window/threshold
Errored-symbol Event period (in
seconds)
Errored-symbol Event threshold
Errored-frame Event period (in
seconds)
Errored-frame Event threshold
Errored-frame-period Event period
(in ms)
Errored-frame-period Event
threshold
Description
Detection intervals and triggering thresholds configured for link events.
Errored symbol event detection interval, which defaults to one second.
Errored symbol event triggering threshold, which defaults to 1.
Errored frame event detection interval, which defaults to one second.
Errored frame event triggering threshold, which defaults to 1.
Errored frame period event detection interval, which defaults to 1000
milliseconds.
Errored frame period event triggering threshold, which defaults to 1.
5
:
1
:
1
:
1
:
1
:
1000
:
1
:
60
:
1

Advertisement