By default, no track entry exists.
After a track entry is created, you cannot change its settings except the delay time. To change the delay
time, use the track interface protocol delay command. To modify other settings of this track entry, first
delete the entire track entry, and then create a new track entry.
Related commands: display track; display ip interface brief (Layer 3
display ipv6 interface (Layer 3
Examples
# Create track entry 1, and associate it with the IPv4 protocol status of VLAN-interface 2.
<Sysname> system-view
[Sysname] track 1 interface vlan-interface 2 protocol ipv4

track nqa

Syntax
track track-entry-number nqa entry admin-name operation-tag reaction item-number [ delay { negative
negative-time | positive positive-time } * ]
undo track track-entry-number
View
System view
Default level
2: System level
Parameters
track-entry-number: Specifies a track entry ID, in the range of 1 to 1024.
entry admin-name operation-tag: Specifies the NQA test group to be associated with the track entry.
admin-name is the name of the NQA test group administrator who creates the NQA operation, and is
a case-insensitive string of 1 to 32 characters. operation-tag is the NQA operation tag, a case-insensitive
string of 1 to 32 characters.
reaction item-number: Specifies the reaction entry to be associated with the track entry. item-number is
the reaction entry ID, in the range of 1 to 10.
delay: Specifies that the track module notifies the application modules of the track entry status change
after a specific delay time. If this keyword is not provided, the track module notifies the application
modules immediately when the track entry status changes.
negative negative-time: Specifies the delay time for the track module to notify the application modules
that the status of the track entry changes to Negative. negative-time represents the delay time in seconds,
in the range of 1 to 300.
positive positive-time: Specifies the delay time for the track module to notify the application modules that
the status of the track entry changes to Positive. positive-time represents the delay time in seconds, in the
range of 1 to 300.
Description
Use track nqa to create a track entry, associate it with the specified reaction entry of the NQA test group,
and specify the delay time for the track module to notify the application modules when the status of the
track entry changes.
Use undo track to remove the track entry.
IP Services Command Reference).