Cfd Ma - HP 6125G Command Reference Manual

High availability command reference
Hide thumbs Also See for 6125G:
Table of Contents

Advertisement

Examples
# Enable LB to check the status of the link between MEP 1 101 and MEP 2001 (whose MAC address is
0010-FC00-6512) in service instance 1 (assume that the link status is normal).
<Sysname> cfd loopback service-instance 1 mep 1101 target-mep 2001
Loopback to 0010-FC00-6512 with the sequence number start from 1101-43404:
Reply from 0010-FC00-6512: sequence number=1101-43404 time=5ms
Reply from 0010-FC00-6512: sequence number=1101-43405 time=5ms
Reply from 0010-FC00-6512: sequence number=1101-43406 time=5ms
Reply from 0010-FC00-6512: sequence number=1101-43407 time=5ms
Reply from 0010-FC00-6512: sequence number=1101-43408 time=5ms
Send:5
# Enable LB to check the status of the link between MEP 1 101 and MEP 2001 (whose MAC address is
0010-FC00-6512) in service instance 1 (assume that the link status is abnormal).
<Sysname> cfd loopback service-instance 1 mep 1101 target-mep 2001
Sequence number=1101-43404: Request timed out
Sequence number=1101-43405: Request timed out
Sequence number=1101-43406: Request timed out
Sequence number=1101-43407: Request timed out
Sequence number=1101-43408: Request timed out
Send:5
Table 9 Command output
Field
Loopback to 0010-FC00-6512 with the sequence
number start from 1101-43404
sequence number
time=5ms
Request timed out
Send
Received
Lost

cfd ma

Syntax
cfd ma ma-name md md-name vlan vlan-id
undo cfd ma ma-name md md-name
View
System view
Default level
2: System level
Received:5
Lost:0
Received:0
Lost:5
Description
Sends LBMs to 0010-FC00-6512 with the sequence
number starting with 1101-43404.
Sequence number in the LBR messages.
The interval between the sending of LBMs and
receiving of LBRs is 5 milliseconds.
The request is timed out because no LBR is received
within 5 milliseconds.
Number of LBMs sent.
Number of LBR messages received.
Number of lost LBRs.
24

Advertisement

Table of Contents
loading

This manual is also suitable for:

6125 blade switch series

Table of Contents